Site Map
|
THE COMPUTERIZED DEVICE DESIGNED TO CONTROL
THE SURFACE INSULATION RESISTIVITY OF COATINGS
FRANKLIN TESTER TF-100

The measuring device Franklin tester is designed to measure
the insulation resistivity of coating and its mineral components on the surface
of electrotechnical steel sheet as well as applied enamel to generator stator
core laminations according to the ASTM A717/ A717 M - 95 Standard.
Microprocessor controlled power supply with bi-directional servomotor and
electronic regulator of adjustments rate allows setting the specific pressure
forces of measuring head (which contains 10 electrodes) on the tested object.
The tested object is placed on the hot plate of the measuring table, which is
pressed down to the measuring head as well as warmed up according to the settled
pressure and temperature values.
In the moment of switching on the measuring procedure, two mills point wise
remove the coat. It is ensure the galvanic contact of the device with electrotechnical
sheet. The quality of this contact as well as measuring procedure is controlled
automatically. When pressure and temperature are stabilized and after 30 seconds,
the value of current is measured under strictly specified applied voltage. The
measured current flows between the electrodes and the sheet, which is the base
of insulating coat.
The measuring table automatically comes back to the initial position after the
measurement procedure is finished. It allows fixing new tested specimen and
performing new measurement.
The device is fully automated including the procedure of the pressure and
temperature setting, measurement, calculations and the recording of measurement
results.
TECHNICAL DATA:
|
| » | Number of electrodes | 10 |
| » | The surface of one electrode | 64.5mm2 |
| » | Total surface of electrodes | 6.45cm2 |
| » | Pressure adjustment in | MPa lub psi |
| » | The range of pressure adjustment | (2.0 ÷ 7.0)MPa |
| » | Accuracy of pressure adjustment | ±0.5% |
| » | Temperature adjustment in Celsius or Fahrenheit degrees | |
| » | The range of adjustment from ambient temperature | to 200 °C or to 392 °F |
| » | Accuracy of temperature adjustment | ±5 °C lub ±2.7 °F |
| » | Voltage supply of the tested object | (0.500 ÷ 0.001)V |
| » | The range of current measurement | 1.1A |
| » | Accuracy of current measurement | ±0.001A |
| » | Quality control of the contact with
the base of the coat (electrotechnical sheet) | automatic |
| » | The control of measurement correctness | continuous |
| » | The number of saved results | max. 350 |
| » | The possibility of data transmission to the external computer | by series interface |
| » | Measurement results presentation by means of: | |
|
- liquid-crystal display of the device,
- monitor, after connection the device to the computer,
| |
| » | Resistivity is determined from the equation: | |
|
- where: I [A] - the value of current strength under voltage supply equals 0.500V,
- 6.45 cm2 - total surface of contact of electrodes.
|  |
Power supply:
» Three-phase power supply 3*400V +5% -10%
» Frequency 50 Hz
» Power 2 kVA
The performance capabilities of the tester ensure the measuring precision acquired
for the unequivocal evaluation of both insulating coat of the sheets and the quality
of varnish procedure. Franklin tester is especially valuable as basic equipment for
research laboratories and companies, which are engaged in technology, production and
utilisation of electrotechnical steel.
Top
|